{"product_id":"dantherm-aerial-aercube-turbine-vp-6-insulation-drying","title":"Dantherm Aerial AERCUBE Turbine VP 6 – Vacuum and Pressure Turbine for Insulation Layer Drying (220 mbar)","description":"\u003cdiv style=\"background:#eef4fa;border:2px solid #2a6fb0;padding:12px 16px;border-radius:8px;margin:0 0 20px 0;\"\u003e\u003cp style=\"margin:0;color:#0f1923;\"\u003e\u003cstrong\u003eAvailable to order:\u003c\/strong\u003e typical lead time 5–10 working days. We confirm the exact date after your order or enquiry.\u003c\/p\u003e\u003c\/div\u003e\n\u003cp\u003eThe \u003cstrong\u003eDantherm Aerial AERCUBE Turbine VP 6\u003c\/strong\u003e is a noise box with a brushless high-performance turbine for drying screed insulation layers and cavities after water damage. It works as a vacuum pump with up to \u003cstrong\u003e220 mbar\u003c\/strong\u003e negative pressure or as a pressure pump with up to \u003cstrong\u003e270 mbar\u003c\/strong\u003e overpressure, has a maximum motor power of \u003cstrong\u003e1,280 W\u003c\/strong\u003e and delivers \u003cstrong\u003e80 to 250 m³\/h\u003c\/strong\u003e in four stages. At \u003cstrong\u003e15 kg\u003c\/strong\u003e, the stackable unit is designed for insulation layer drying in rooms of up to \u003cstrong\u003e70 m²\u003c\/strong\u003e, and a night mode allows operation in occupied buildings.\u003c\/p\u003e\n\u003ch4\u003eHow it works\u003c\/h4\u003e\n\u003cp\u003eIn suction (vacuum) mode, the VP 6 extracts the moist air from the insulation layer under the screed through a hose system; in pressure mode it blows air into cavities that are difficult to access. On the suction side the turbine must always be operated with a suitable air filter system; the manufacturer recommends the AERCUBE HF 2 filter system. In pressure mode the process air reaches approx. 70 °C, so check that the floor construction can withstand this temperature.\u003c\/p\u003e\n\u003cp\u003eThe power stage is chosen according to the room size: stage 1 up to 15 m², stage 2 up to 30 m², stage 3 up to 50 m² and stage 4 up to 70 m². The control panel with display shows the current stage and a bar graph of the back pressure; the smaller the deflection, the more efficient the drying. The \"Info\" button shows the total operating hours, the temperature and differential pressure of the process air, and the version and serial number of the electronics; the display language can be changed. The night mode (available in stages 2 to 4) switches the turbine to quiet operation for a 10-hour countdown and then returns to the last selected stage. When switched on, the unit starts automatically in the last selected stage. If the turbine is overloaded for 15 seconds it switches off while the cooling air fan keeps running; it is restarted with the reset button.\u003c\/p\u003e\n\u003cp\u003eThe integrated MID-compliant energy meter is calibrated and cannot be reset, so the energy consumption of each job can be documented, for example for insurers. In the standard version, the consumption of devices connected to the unit's socket is not counted by the MID meter.\u003c\/p\u003e\n\u003ch4\u003eKey benefits\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum and pressure operation\u003c\/strong\u003e — up to 220 mbar negative pressure and 270 mbar overpressure for insulation layer and cavity drying.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour power stages\u003c\/strong\u003e — 80, 140, 190 and 250 m³\/h, matched to room sizes from 15 m² to 70 m².\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocumented energy consumption\u003c\/strong\u003e — calibrated, non-resettable MID-compliant energy meter plus operating hours counter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNight mode and silencer\u003c\/strong\u003e — integrated sound absorber; 61 dB(A) at 1 m and 57 dB(A) at 3 m in normal operation, quieter in night mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess monitoring\u003c\/strong\u003e — the back-pressure and differential-pressure display shows the drying progress and possible blockages in the hose system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight and stackable\u003c\/strong\u003e — 15 kg, robust stackable plastic housing with fixing points for a lashing strap system, plus a crane eye mounting option.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtected for site use\u003c\/strong\u003e — IP44, key lock, overheating protection and integrated cable winding for the 4.5 m power cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTypical applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation layer drying after water damage: screed insulation layers in flats, houses and offices\u003c\/li\u003e\n\u003cli\u003eCavity drying: suspended ceilings, wall cavities and installation shafts\u003c\/li\u003e\n\u003cli\u003eUnderfloor heating leaks: drying under the screed without dismantling\u003c\/li\u003e\n\u003cli\u003eFlat roof renovation: dehumidifying the thermal insulation by the vacuum method\u003c\/li\u003e\n\u003cli\u003eNew buildings: accelerating the drying of residual moisture in the screed\u003c\/li\u003e\n\u003cli\u003eWater damage restoration in occupied and unoccupied buildings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOperating conditions and installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: 0 °C to 38 °C (the operating manual specifies 0 °C to +35 °C)\u003c\/li\u003e\n\u003cli\u003eElectrical supply: 230 V, 50 Hz, 1,280 W; the socket and supply must be sufficiently fused and a residual current circuit breaker (RCD) is required on site\u003c\/li\u003e\n\u003cli\u003eProtection class: IP44\u003c\/li\u003e\n\u003cli\u003eFor conveying air and non-explosive gases and gas-air mixtures at atmospheric pressure only.\u003c\/li\u003e\n\u003cli\u003eAlways operate the suction side with a suitable air filter system (HF 2 recommended); in suction mode a water separator may also be required.\u003c\/li\u003e\n\u003cli\u003eUse hoses with a diameter of 50 mm; smaller hoses lead to higher energy consumption and longer drying times.\u003c\/li\u003e\n\u003cli\u003eSet up on a level, firm surface and secure against tipping; carry the unit only by the handles or recessed grips.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eScope of delivery\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNoise box VP 6\u003c\/li\u003e\n\u003cli\u003eOne operating manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFilter system, water separator, hoses and connectors shown in application photos are not included.\u003c\/p\u003e\n\u003ch4\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eRequired (not included):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir filter system for the suction side\u003c\/strong\u003e — the manufacturer recommends the AERCUBE HF 2 filter system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOptional, depending on the drying set-up:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAERCUBE water separator VT 2\u003c\/strong\u003e — may be required in suction mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAERCUBE silencer SD 2 with pre-filter 6005-0007\u003c\/strong\u003e — for pressure mode (alternatively HF 2).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAerial air cooling filter for VP 6\u003c\/strong\u003e — product code 2001229.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAerial Superflextract hose Ø 50 mm\u003c\/strong\u003e — product code 2002247; Ø 38 mm — product code 2002245.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAerial PE hose Ø 50 mm\u003c\/strong\u003e — product code 2002246.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAerial floor connecting piece\u003c\/strong\u003e — Ø 50 mm product code 2002264; Ø 38 mm product code 2002263.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAerial hose distributors\u003c\/strong\u003e — T Ø 50 mm 2002258, T Ø 50 mm with thread 2002257, T Ø 40 mm 2002261, T Ø 38 mm 2002256, Y Ø 50 mm 2002260, Y Ø 38 mm 2002259.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAerial combi connector\u003c\/strong\u003e — product code 2002267.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAerial adaptor plate\u003c\/strong\u003e — product code 2000555.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAerial lashing strap for AERCUBE units\u003c\/strong\u003e — product code 2002291.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical data\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 2000216 · EAN: 4260393630697\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct width:\u003c\/strong\u003e 390 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct length:\u003c\/strong\u003e 507 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct height:\u003c\/strong\u003e 455 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct weight:\u003c\/strong\u003e 15 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended room size:\u003c\/strong\u003e 70 m²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended room volume:\u003c\/strong\u003e 175 m³\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. negative pressure:\u003c\/strong\u003e 220 mbar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. overpressure:\u003c\/strong\u003e 270 mbar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor power max.:\u003c\/strong\u003e 1.28 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable length:\u003c\/strong\u003e 4.5 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains connection and frequency:\u003c\/strong\u003e 230 V, 50 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower consumption:\u003c\/strong\u003e 1,280 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter class:\u003c\/strong\u003e F7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation – max. temperature:\u003c\/strong\u003e 38 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation – min. temperature:\u003c\/strong\u003e 0 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e plastic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP protection class:\u003c\/strong\u003e IP44\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection against contact:\u003c\/strong\u003e protected against access with a wire (Ø ≥ 1.0 mm, length 100 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection against water:\u003c\/strong\u003e protection against water splashing from all directions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection against foreign bodies:\u003c\/strong\u003e protected against solid foreign bodies Ø ≥ 1 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir volume:\u003c\/strong\u003e stage 1: 80 m³\/h; stage 2: 140 m³\/h; stage 3: 190 m³\/h; stage 4: 250 m³\/h (free blowing); max. 250 m³\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSound level:\u003c\/strong\u003e 57 dB(A) at 3 m distance; 61 dB(A) at 1 m distance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment:\u003c\/strong\u003e cable winding, energy consumption meter (MID-compliant), key lock, night mode, on\/off switch, operating hours counter, overheating protection, silencer, socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e stackable noise box with plastic housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFrequently asked questions\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eCan the VP 6 be operated without a filter?\u003c\/strong\u003e\u003cbr\u003eNo. On the suction side the VP 6 must always be operated with a suitable air filter system; the manufacturer recommends the AERCUBE HF 2 filter system, which protects the turbine against dust, moisture and contamination from the insulation layer. The filter system is not included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich power stage should I choose?\u003c\/strong\u003e\u003cbr\u003eThe manual relates the stages to the room size: stage 1 up to 15 m², stage 2 up to 30 m², stage 3 up to 50 m² and stage 4 up to 70 m². The back-pressure bar graph on the display helps to check the setting: the smaller the deflection, the more efficient the drying.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the VP 6 run at night in occupied rooms?\u003c\/strong\u003e\u003cbr\u003eYes, the night mode switches the turbine to quiet operation for 10 hours and is available in stages 2 to 4. According to the operating manual, the sound level in night mode is 56 dB(A) at 1 m and 54 dB(A) at 3 m.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the MID meter also measure devices plugged into the VP 6?\u003c\/strong\u003e\u003cbr\u003eNo. In the standard version, the energy consumption of devices connected to the unit's socket is not counted by the calibrated MID meter. The meter records the consumption of the VP 6 itself.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOriginal Aerial equipment (Dantherm Group)\u003c\/strong\u003e — supplied with full manufacturer documentation by BMB Rheinland, your authorised distribution partner.\u003c\/p\u003e\u003cp\u003ePlanning a project or a larger requirement? \u003ca href=\"\/pages\/contact\"\u003eRequest a quote\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/danthermpublicfiles.blob.core.windows.net\/en-aerial-manuals\/Aerial-VP-6-user-manual-5506-0064-EN-DE.pdf\" target=\"_blank\"\u003e📄 Operating manual incl. CE declaration Aerial AERCUBE VP 6 (DE\/EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Dantherm","offers":[{"title":"Default Title","offer_id":58787174285656,"sku":"2000216","price":3802.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0962\/3932\/1432\/files\/AERCUBE-Turbine-VP-6-163765-1749734727.jpg?v=1791978533","url":"https:\/\/shop.bmbrheinlandgmbh.com\/products\/dantherm-aerial-aercube-turbine-vp-6-insulation-drying","provider":"BMB Rheinland GmbH","version":"1.0","type":"link"}