{"product_id":"trotec-ld6000-frequency-analysis-set-leak-detection","title":"TROTEC LD6000 – Frequency Analysis Set for Acoustic Leak Detection (0–4,000 Hz)","description":"\u003cdiv style=\"background:#eef4fa;border:2px solid #2a6fb0;padding:12px 16px;border-radius:8px;margin:0 0 20px 0;\"\u003e\u003cp style=\"margin:0;color:#0f1923;\"\u003e\u003cstrong\u003eAvailable to order:\u003c\/strong\u003e typical lead time 5–10 working days. We confirm the exact date after your order or enquiry.\u003c\/p\u003e\u003c\/div\u003e\n\u003cp\u003eThe TROTEC LD6000 frequency analysis set is a complete kit for electro-acoustic leak detection and acoustic line location. Whether you are tracing a line, narrowing down a leak area or pinpointing a leak, the LD6000 and its German-made precision microphones capture, process and display even very small leak noises. The instrument offers \u003cstrong\u003e120 dB amplification\u003c\/strong\u003e, \u003cstrong\u003eup to 256 freely selectable filters\u003c\/strong\u003e, a sound measuring range of \u003cstrong\u003e0 to 4,000 Hz\u003c\/strong\u003e and a colour touch display, and runs for \u003cstrong\u003eup to 14 h continuously\u003c\/strong\u003e on four LR14 batteries. With the optional hydrogen sensor, the same instrument also performs tracer gas leak detection.\u003c\/p\u003e\n\u003ch4\u003eHow it works\u003c\/h4\u003e\n\u003cp\u003eA ground microphone or contact probe is connected to the LD6000 via the bayonet connection; the operator listens through the included sound-insulated headphones and reads the signal on the colour display (480 x 272 pixels, automatically illuminated). The instrument is controlled either via the touchscreen or via buttons and rotary controls. Many typical applications are pre-programmed for quick access, and all filters and parameters are freely configurable.\u003c\/p\u003e\n\u003cp\u003eOperating modes are acoustic leak location (F\u0026amp;L, Smart and long-term measurement), line location by sound and tracer gas leak location. Measuring and device functions include minimum level, averaged level, pulse wave measurement, simultaneous F\u0026amp;L analysis, a logging function, automatic setting of filter frequencies and sensor sensitivity, a preference memory for manual filter settings and sound-level overload protection. With the Smart function (patent pending), leaks can be pinpointed faster. In tracer gas mode, the signal depends on concentration, both optically and acoustically.\u003c\/p\u003e\n\u003ch4\u003eKey benefits\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAcoustic and tracer gas leak detection with one instrument\u003c\/strong\u003e — add the optional LD6000 H2 hydrogen sensor for tracer gas work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColour graphic touch display\u003c\/strong\u003e — high-resolution colour display with touchscreen, plus buttons and rotary controls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart function (patent pending)\u003c\/strong\u003e — for faster pinpointing of leaks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-programmed applications\u003c\/strong\u003e — many typical use cases are ready for quick access, while all filters and parameters remain freely configurable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine location mode\u003c\/strong\u003e — acoustic tracing of pipe routes in addition to leak detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHearing protection\u003c\/strong\u003e — meets the hearing protection requirements of VBG 121 in combination with the original headphones.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision microphones\u003c\/strong\u003e — highly sensitive, robust microphones of German manufacture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong operating time\u003c\/strong\u003e — up to 14 h in continuous operation, up to 40 h with normal use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTypical applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAcoustic water leak detection on pressure pipes: narrowing down the leak area and pinpointing with the ground microphone.\u003c\/li\u003e\n\u003cli\u003eAcoustic line location (pipe tracing).\u003c\/li\u003e\n\u003cli\u003eLong-term acoustic measurement with the logging function (5, 15, 30 or 60 minutes).\u003c\/li\u003e\n\u003cli\u003eNon-destructive leak location in installations flushed with tracer gas (hydrogen), with the optional LD6000 H2 sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOperating conditions and installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -5 °C to +55 °C; storage temperature: -25 °C to +65 °C.\u003c\/li\u003e\n\u003cli\u003eProtection class: IP54 (protected against dust in harmful quantities and against splashing water from all directions).\u003c\/li\u003e\n\u003cli\u003ePower supply: 4 x LR14 (C) 1.5 V batteries; according to the manual, NiMH rechargeable batteries type HR14 1.2 V can also be used.\u003c\/li\u003e\n\u003cli\u003eAccording to the manual, never take measurements on live parts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eScope of delivery\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1 x LD6000 measuring instrument\u003c\/li\u003e\n\u003cli\u003e1 x LD K sound-insulated headphones\u003c\/li\u003e\n\u003cli\u003e1 x LD6000 BM ground microphone, small\u003c\/li\u003e\n\u003cli\u003e1 x LD6000 DA tripod adapter\u003c\/li\u003e\n\u003cli\u003e1 x LD6000 VL extension with tip\u003c\/li\u003e\n\u003cli\u003e1 x LD6000 TG carrying strap\u003c\/li\u003e\n\u003cli\u003e1 x LD6000 transport case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe tracer gas function requires the optional LD6000 H2 hydrogen sensor, which is not included. The operating manual additionally lists a USB PC connection cable in the standard scope of delivery.\u003c\/p\u003e\n\u003ch4\u003eAccessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional:\u003c\/strong\u003e LD6000 BMW wind-protected ground microphone (with dead man's button)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional:\u003c\/strong\u003e LD6000 DM tripod magnet for ground microphone LD6000 BMW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional:\u003c\/strong\u003e LD6000 H2 hydrogen sensor (required for tracer gas leak detection)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional:\u003c\/strong\u003e LD6000 VK connection cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional:\u003c\/strong\u003e MultiMeasure Studio PRO software for professional measurement reports (MultiMeasure Studio STD is available as a download)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical data\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 3110008010 · EAN: 4052138005064\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength without packaging:\u003c\/strong\u003e 210 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength with packaging:\u003c\/strong\u003e 400 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth without packaging:\u003c\/strong\u003e 160 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth with packaging:\u003c\/strong\u003e 255 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight without packaging:\u003c\/strong\u003e 60 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight with packaging:\u003c\/strong\u003e 156 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight without packaging:\u003c\/strong\u003e 1.05 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight including packaging:\u003c\/strong\u003e 5.5 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e colour LCD (automatically illuminated), 480 x 272 pixels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData memory:\u003c\/strong\u003e internal flash memory for up to 20 measurement series and as a buffer for recording long-term measurements of 5, 15, 30 and 60 min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory type:\u003c\/strong\u003e internal flash\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput impedance max.:\u003c\/strong\u003e 10 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput impedance:\u003c\/strong\u003e 1 Ω (operating manual: 1 MΩ)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation, max. temperature:\u003c\/strong\u003e 55 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation, min. temperature:\u003c\/strong\u003e -5 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -25 °C to +65 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmplification:\u003c\/strong\u003e 120 dB (low noise factor)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilters:\u003c\/strong\u003e up to 256 freely selectable (for probe rod and ground microphone)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range, sound:\u003c\/strong\u003e 0 Hz – 4,000 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating modes:\u003c\/strong\u003e acoustic leak location (F\u0026amp;L, Smart, long-term measurement), line location and tracer gas leak location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e touchscreen or buttons and rotary controls (rotary knobs, membrane keypad, touch function)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery monitoring:\u003c\/strong\u003e via microcontroller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterfaces:\u003c\/strong\u003e bayonet (microphone), bayonet (sensor), 6.3 mm jack plug (headphones)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal sensors:\u003c\/strong\u003e sound [digits]\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating time:\u003c\/strong\u003e up to 14 h in continuous operation, up to 40 h with normal use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 4 x LR14\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP protection class:\u003c\/strong\u003e IP54 (complete protection against contact; protection against splashing water from all directions; protected against dust in harmful quantities)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment:\u003c\/strong\u003e acoustic leak location (audible sound) with F + L analysis function; acoustic leak location (audible sound) with Smart analysis function; acoustic long-term measurement (audible sound, logging function); acoustic line location by sound location; acoustic pulse wave measurement; automatic setting of filter frequencies; automatic setting of sensor sensitivity; averaged level; minimum level display; adjustable high-pass and low-pass filters; preference memory for manual filter settings; sound-level overload protection; tracer gas detection with concentration-dependent acoustic and optical signal; tracer gas leak location; up to 256 freely selectable filters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e housing plastic\/metal; aluminium, powder-coated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFrequently asked questions\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eIs the hydrogen sensor for tracer gas detection included?\u003c\/strong\u003e\u003cbr\u003eNo. The LD6000 supports tracer gas leak location, but the LD6000 H2 hydrogen sensor is an optional accessory. The set includes the instrument, headphones, small ground microphone LD6000 BM, tripod adapter, extension with tip, carrying strap and transport case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich batteries does the LD6000 use?\u003c\/strong\u003e\u003cbr\u003eFour LR14 (C) 1.5 V batteries. According to the manual, NiMH rechargeable batteries type HR14 1.2 V can also be used. Operating time is up to 14 h in continuous operation and up to 40 h with normal use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the LD6000 record measurements over a longer period?\u003c\/strong\u003e\u003cbr\u003eYes. The long-term measurement mode with logging function records for 5, 15, 30 or 60 minutes; the internal flash memory stores up to 20 measurement series.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre the headphones suitable for hearing protection?\u003c\/strong\u003e\u003cbr\u003eTROTEC states that the LD6000 meets the hearing protection requirements of VBG 121 in combination with the original LD K headphones, which are included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOriginal TROTEC equipment\u003c\/strong\u003e — supplied with full manufacturer documentation by BMB Rheinland, your authorised distribution partner.\u003c\/p\u003e\u003cp\u003ePlanning a project or a larger requirement? \u003ca href=\"\/pages\/contact\"\u003eRequest a quote\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/de.trotec.com\/fileadmin\/downloads\/Leckageortung\/LD6000\/TRT-BALD6000-WM-05-EN.pdf\" target=\"_blank\"\u003e📄 Operating manual TROTEC LD6000 (EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/de.trotec.com\/fileadmin\/downloads\/Leckageortung\/LD6000\/TRT-BALD6000-WM-06-DE.pdf\" target=\"_blank\"\u003e📄 Operating manual TROTEC LD6000 (DE)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"TROTEC","offers":[{"title":"Default Title","offer_id":58788072489304,"sku":"3110008010","price":3510.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0962\/3932\/1432\/files\/LD6000-Frequenzanalyse-Set-66588-1507646003.jpg?v=1791984134","url":"https:\/\/shop.bmbrheinlandgmbh.com\/products\/trotec-ld6000-frequency-analysis-set-leak-detection","provider":"BMB Rheinland GmbH","version":"1.0","type":"link"}