{"product_id":"trotec-pd200-impulse-current-leak-detection-set","title":"TROTEC PD200 – Impulse Current Leak Detection Set (200 m ring line)","description":"\u003cdiv style=\"background:#eef4fa;border:2px solid #2a6fb0;padding:12px 16px;border-radius:8px;margin:0 0 20px 0;\"\u003e\u003cp style=\"margin:0;color:#0f1923;\"\u003e\u003cstrong\u003eAvailable to order:\u003c\/strong\u003e typical lead time 5–10 working days. We confirm the exact date after your order or enquiry.\u003c\/p\u003e\u003c\/div\u003e\n\u003cp\u003eThe \u003cstrong\u003eTROTEC PD200\u003c\/strong\u003e is a professional impulse current measuring system for locating earthed leaks in non-conductive membranes, for example on foil and bitumen flat roofs. The set combines the \u003cstrong\u003ePD200 G\u003c\/strong\u003e impulse generator, built into a transport case with carrying handle, with the battery-powered \u003cstrong\u003ePD200 E\u003c\/strong\u003e impulse receiver and all standard accessories, including a \u003cstrong\u003e200 m\u003c\/strong\u003e ring line. It runs on \u003cstrong\u003e220–240 V, 50–60 Hz\u003c\/strong\u003e, weighs \u003cstrong\u003e8.5 kg\u003c\/strong\u003e complete with standard accessories and has protection class \u003cstrong\u003eIP54\u003c\/strong\u003e. Its compact dimensions allow it to be carried up to the roof, for example via safety ladders.\u003c\/p\u003e\n\u003ch4\u003eHow it works\u003c\/h4\u003e\n\u003cp\u003eThe method requires water on and below the waterproofing layer: the moisture conducts the electrical current, so the membrane being tested must be wet enough (if necessary, it is watered beforehand). An uninsulated ring line is laid in a closed loop around the area to be tested, at least 0.5 m from the roof edge and in direct contact with the waterproofing. According to the operating manual, the generator emits current pulses at a voltage of 40 V; the current finds its way through the moisture to the leak. With the two measuring rods, the receiver measures the potential difference, and its pointer deflects towards the higher potential, guiding you step by step to the point where moisture penetrates.\u003c\/p\u003e\n\u003cp\u003eClearly visible signal lamps on top of the case, protected by a sturdy steel bracket, show the status: the green lamp lights up when a pulse is delivered to the ring line, the red lamp when there is a short circuit. An integrated buzzer can be switched on to add an audible signal. In the event of a short circuit, the output signal is switched off automatically and an alarm sounds; an integrated short-circuit test is part of the equipment.\u003c\/p\u003e\n\u003ch4\u003eKey benefits\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-destructive leak location\u003c\/strong\u003e — pinpoint location of leaks in foil and bitumen roofs and other flat waterproofing without opening the roof.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorks under ballast\u003c\/strong\u003e — leak location is also possible on flat roofs with ballast such as gravel, green roofs or paving slabs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinds capillary leaks\u003c\/strong\u003e — also detects capillary leaks that cannot be found with the smoke gas method.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisible and audible signals\u003c\/strong\u003e — green pulse lamp and red short-circuit lamp, visible from almost any angle across the roof, plus a switchable signal tone.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit protection\u003c\/strong\u003e — integrated short-circuit test, automatic shut-off of the output signal and alarm signal in the event of a short circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete, compact set\u003c\/strong\u003e — all necessary accessories in one compact case; robust, splash-proof design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimple receiver\u003c\/strong\u003e — compact, battery-powered receiver with carrying strap and a minimum of controls.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTypical applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWarm roofs, cold roofs and green flat roofs\u003c\/li\u003e\n\u003cli\u003eRoof terraces and balconies\u003c\/li\u003e\n\u003cli\u003eFoil-lined ponds and swimming pools\u003c\/li\u003e\n\u003cli\u003eFoil-lined landfills and heaps\u003c\/li\u003e\n\u003cli\u003eLeak testing of hall floor sealing for LAU and HBV facilities (German Water Resources Act, WHG)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOperating conditions and installation\u003c\/h4\u003e\n\u003cp\u003eMains connection 220–240 V, 50–60 Hz; the mains connection must have a proper protective earth conductor. The receiver runs on 6 batteries type LR06 \/ AM-3 \/ AA \/ Mignon. Protection class IP54 according to TROTEC product data. According to the operating manual, operating and storage temperature is 0 °C to +40 °C. The membrane being tested must be sufficiently moist to conduct the current pulses, and the ring line must lie directly on the waterproofing; with thicker coverings such as soil or planting, the waterproofing must be exposed at the ring line. Do not use the device in potentially explosive areas, for measurements in liquids or on live parts.\u003c\/p\u003e\n\u003ch4\u003eScope of delivery\u003c\/h4\u003e\n\u003cp\u003eAccording to TROTEC:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x transport case with carrying handle and integrated PD200 G impulse generator with mains cable (220–240 V, 50–60 Hz)\u003c\/li\u003e\n\u003cli\u003e1 x each connection cable with crocodile clip, black and red, length 8 m (stored in the lid)\u003c\/li\u003e\n\u003cli\u003e1 x roll PD200 ring line, length 200 m\u003c\/li\u003e\n\u003cli\u003e1 x roll PD200 earthing cable extension, red, length 25 m\u003c\/li\u003e\n\u003cli\u003e2 x dismountable measuring rods with rubber handle (3-part, length 1.00 m), incl. 1 x clamping spring and 1 x integrated unwinding aid for the ring line\u003c\/li\u003e\n\u003cli\u003e1 x each connecting cable for the measuring rods, red and black\u003c\/li\u003e\n\u003cli\u003e1 x PD200 E impulse receiver with carrying strap\u003c\/li\u003e\n\u003cli\u003e6 x batteries type LR06 \/ AM-3 \/ AA \/ Mignon\u003c\/li\u003e\n\u003cli\u003e1 x operating manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAccessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional:\u003c\/strong\u003e PD series gravel tip — recommended by the manufacturer when the ballast consists of poured gravel or other granulate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement parts offered by TROTEC for the PD series:\u003c\/strong\u003e ring line, earthing cable extension, measuring rods and measuring lead for the rods.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical data\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 3510010012 · EAN: 4052138009338\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength without packaging:\u003c\/strong\u003e 265 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth without packaging:\u003c\/strong\u003e 465 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight without packaging:\u003c\/strong\u003e 253 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight without packaging:\u003c\/strong\u003e 8.5 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight including packaging:\u003c\/strong\u003e 12.2 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of batteries per unit:\u003c\/strong\u003e 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection voltage – impulse current:\u003c\/strong\u003e 220 - 240 V, 50 - 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenerator principle – impulse current:\u003c\/strong\u003e voltage generator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment:\u003c\/strong\u003e acoustic alarm signal in the event of a short circuit; acoustic signal transmitter; automatic shut-off of the output signal in the event of a short circuit; visual signal transmitter; integrated short-circuit test\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice control:\u003c\/strong\u003e rotary knobs; push buttons\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterfaces:\u003c\/strong\u003e banana plugs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal sensors:\u003c\/strong\u003e current [µA]\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenerator unit:\u003c\/strong\u003e impulse current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e internal (battery) – (receiver)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign – housing:\u003c\/strong\u003e metal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP protection class:\u003c\/strong\u003e IP54\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection against contact:\u003c\/strong\u003e complete protection against contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection against water:\u003c\/strong\u003e protection against splashing water from all directions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection against foreign bodies:\u003c\/strong\u003e protected against dust in harmful quantities\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePD200 G generator – external dimensions (description):\u003c\/strong\u003e 305 x 420 x 360 mm; weight complete with standard accessories 8.5 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePD200 E receiver:\u003c\/strong\u003e external dimensions 160 x 80 x 55 mm; weight (incl. batteries) 550 g; 6 x battery type LR06 \/ AM-3 \/ AA \/ Mignon\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFrequently asked questions\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the roof have to be wet for the measurement?\u003c\/strong\u003e\u003cbr\u003eYes. The method needs a moist, electrically conductive waterproofing layer, whether the surface is wet, covered with gravel or planted. If necessary, the waterproofing must be watered additionally.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I locate leaks on a gravel or green roof without removing the ballast?\u003c\/strong\u003e\u003cbr\u003eLeak location is possible on flat roofs with ballast such as gravel, planting or paving. The ring line must lie directly on the waterproofing: with poured gravel, the optional gravel tip is recommended; with thicker coverings such as soil or planting, the waterproofing must be exposed where the ring line is laid.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply does the PD200 need?\u003c\/strong\u003e\u003cbr\u003eThe generator is connected to 220–240 V, 50–60 Hz mains power with a proper protective earth conductor. The receiver runs on 6 batteries type LR06 (AA), which are included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens in the event of a short circuit?\u003c\/strong\u003e\u003cbr\u003eThe red signal lamp lights up, an alarm sounds and the output signal is switched off automatically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOriginal TROTEC equipment\u003c\/strong\u003e — supplied with full manufacturer documentation by BMB Rheinland, your authorised distribution partner.\u003c\/p\u003e\u003cp\u003ePlanning a project or a larger requirement? \u003ca href=\"\/pages\/contact\"\u003eRequest a quote\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/de.trotec.com\/fileadmin\/downloads\/Leckageortung\/PD200\/TRT-BA-PD200-TC-002-EN.pdf\" target=\"_blank\"\u003e📄 Operating manual TROTEC PD200 (EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/de.trotec.com\/fileadmin\/downloads\/Leckageortung\/PD200\/TRT-BA-PD200-TC-002-DE.pdf\" target=\"_blank\"\u003e📄 Operating manual TROTEC PD200 (DE)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"TROTEC","offers":[{"title":"Default Title","offer_id":58788124131672,"sku":"3510010012","price":3249.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0962\/3932\/1432\/files\/Impulsstrommessger_C3_A4t-PD200-66894-1507646040.jpg?v=1791984392","url":"https:\/\/shop.bmbrheinlandgmbh.com\/products\/trotec-pd200-impulse-current-leak-detection-set","provider":"BMB Rheinland GmbH","version":"1.0","type":"link"}