{"product_id":"trotec-tfv-600-radial-fan","title":"TROTEC TFV 600 – Radial Fan (16,000 m³\/h)","description":"\u003cdiv style=\"background:#eef4fa;border:2px solid #2a6fb0;padding:12px 16px;border-radius:8px;margin:0 0 20px 0;\"\u003e\u003cp style=\"margin:0;color:#0f1923;\"\u003e\u003cstrong\u003eAvailable to order:\u003c\/strong\u003e typical lead time 5–10 working days. We confirm the exact date after your order or enquiry.\u003c\/p\u003e\u003c\/div\u003e\n\u003cp\u003eThe TROTEC TFV 600 is a high-pressure \u003cstrong\u003eradial fan\u003c\/strong\u003e for large-volume supply and extract ventilation. It delivers up to \u003cstrong\u003e16,000 m³\/h\u003c\/strong\u003e free-blowing and still \u003cstrong\u003e10,000 m³\/h at 4,000 Pa\u003c\/strong\u003e, with a maximum pressure of \u003cstrong\u003e4,900 Pa\u003c\/strong\u003e, and runs on \u003cstrong\u003e400 V\u003c\/strong\u003e with a star-delta soft start as standard. The fan is designed for high air volumes against high back pressure, even over long runs of several connected air transport hoses: according to TROTEC it maintains a high air volume over hose distances of 50 metres with several bends. This is the standard version without explosion protection; for potentially explosive atmospheres TROTEC offers the separate TFV 600 Ex.\u003c\/p\u003e\n\u003ch4\u003eHow it works\u003c\/h4\u003e\n\u003cp\u003eUnlike an axial fan, the TFV 600 moves the air perpendicular to the impeller axis on the principle of a centrifuge: the air is pressed outwards and compressed in a spiral (volute) housing. The result is a stable characteristic curve and continuously high pressure on long hose runs. The fan can be connected to intake ducts as well as to discharge ducts. It is supplied ready for connection; the mains connection box holds the control and monitoring components and the CEE 63 A plug connection. According to the operating manual, you switch on the main switch, briefly check the direction of rotation against the arrows on the housing, and then start the fan with the \"control on\" button: it starts in star mode as a soft start and switches to delta mode after a short time to deliver its full output for continuous operation. Indicator lamps show operation and faults, and the \"control off\" button stops the fan after a short run-down.\u003c\/p\u003e\n\u003ch4\u003eKey benefits\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh pressure on long hose runs\u003c\/strong\u003e — up to 4,900 Pa and 10,000 m³\/h at 4,000 Pa, for hose distances of 50 metres with several bends.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoft start as standard\u003c\/strong\u003e — star-delta circuit included for a gentle start-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor dusty environments\u003c\/strong\u003e — the fan motor sits outside the main air flow, so the fan can also be used in very dusty rooms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply or extract\u003c\/strong\u003e — connects to both intake and discharge ducts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust housing\u003c\/strong\u003e — powder-coated steel housing with a highly resistant two-component paint finish for aggressive environments, splash-proof design to IP55; on request in any desired steel grade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMade in Germany\u003c\/strong\u003e — development, design and manufacture 100 % TROTEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTypical applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSupply and extract ventilation of duct and pipe systems\u003c\/li\u003e\n\u003cli\u003eVentilation of tunnel installations\u003c\/li\u003e\n\u003cli\u003eVentilation during welding work\u003c\/li\u003e\n\u003cli\u003eSealing and floor coating work in civil engineering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOperating conditions and installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient temperature range: -20 °C to 40 °C\u003c\/li\u003e\n\u003cli\u003eMaximum conveyed medium temperature: 80 °C\u003c\/li\u003e\n\u003cli\u003eElectrical supply: 400 V, 50 Hz; rated current 34 A; recommended fuse 32 A; connection plug CEE 63 A\u003c\/li\u003e\n\u003cli\u003eProtection: IP55 (complete protection against contact, protected against dust in harmful quantities, protected against water jets from any angle)\u003c\/li\u003e\n\u003cli\u003eIntake nozzle 515 mm; outlet nozzle 515 mm\u003c\/li\u003e\n\u003cli\u003eNot explosion-protected: the operating manual states that the unit must not be operated or set up in fire- or explosion-hazardous rooms; only the Ex versions are approved for explosive atmospheres.\u003c\/li\u003e\n\u003cli\u003eBefore starting, check the direction of rotation against the arrows on the housing (see operating manual).\u003c\/li\u003e\n\u003cli\u003eMaintenance: the manual asks for all installed components to be checked at the latest every 6 months or every 4,000 operating hours and cleaned or replaced as needed; clean the blower with compressed air, not with a pressure washer.\u003c\/li\u003e\n\u003cli\u003eHandling: suitable for crane and forklift handling (with the optional transport frame: forklift slots and crane lifting corners)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eScope of delivery\u003c\/h4\u003e\n\u003cp\u003eThe scope of delivery follows the manufacturer's specification; please ask us if you need a detailed list. Please note: the transport frame shown in the product photos is \u003cstrong\u003enot included\u003c\/strong\u003e. It is available as an optional accessory. In the standard version the fan is supplied without a frame for stationary use.\u003c\/p\u003e\n\u003ch4\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eNo accessories are required for operation. Optional, available on request:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTransport frame made of galvanised steel with robust transport castors, forklift slots and crane lifting corners; stackable two-high for transport and storage\u003c\/li\u003e\n\u003cli\u003eHousing in other steel grades on request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical data\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 1510002040 · EAN: 4052138009345\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct width:\u003c\/strong\u003e 1,250 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct length:\u003c\/strong\u003e 1,305 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct height:\u003c\/strong\u003e 1,170 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct weight:\u003c\/strong\u003e 233 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntake nozzle:\u003c\/strong\u003e 515 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlet nozzle:\u003c\/strong\u003e 515 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan stages:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir outlet speed:\u003c\/strong\u003e 21 m\/s (75.6 km\/h)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. conveyed medium temperature:\u003c\/strong\u003e 80 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. air volume, free-blowing:\u003c\/strong\u003e 16,000 m³\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir volume at 4,000 Pa air pressure:\u003c\/strong\u003e 10,000 m³\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. air pressure:\u003c\/strong\u003e 4,900 Pa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e 34 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains connection and frequency:\u003c\/strong\u003e 400 V, 50 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower consumption:\u003c\/strong\u003e 18,500 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended fuse:\u003c\/strong\u003e 32 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature range (operation, storage, working environment):\u003c\/strong\u003e min. -20 °C, max. 40 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan blades:\u003c\/strong\u003e metal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan type:\u003c\/strong\u003e radial\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment:\u003c\/strong\u003e star-delta circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir flow:\u003c\/strong\u003e blowing, suction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e housing powder-coated, steel; mobility: crane, forklift\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection plug:\u003c\/strong\u003e CEE 63 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP rating:\u003c\/strong\u003e IP55 (complete protection against contact; protection against water jets from any angle; protected against dust in harmful quantities)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise level:\u003c\/strong\u003e 84 dB(A) at 1 m; 78 dB(A) at 3 m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFrequently asked questions\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eCan the TFV 600 be used in potentially explosive areas?\u003c\/strong\u003e\u003cbr\u003eNo. The TFV 600 is the standard version; its operating manual states that it must not be operated in fire- or explosion-hazardous rooms. For Ex areas TROTEC offers the explosion-protected TFV 600 Ex.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat electrical supply does the TFV 600 need?\u003c\/strong\u003e\u003cbr\u003eA 400 V, 50 Hz connection. The rated current is 34 A, the recommended fuse is 32 A, and the fan has a CEE 63 A connection plug. Power consumption is 18,500 W.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the transport frame shown in the photos included?\u003c\/strong\u003e\u003cbr\u003eNo. The standard version comes without a frame. The galvanised steel frame with transport castors, forklift slots and crane lifting corners is available as an optional accessory and allows two units to be stacked.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often does the fan need maintenance?\u003c\/strong\u003e\u003cbr\u003eThe operating manual asks for all installed components to be checked at the latest after 6 months or every 4,000 operating hours and cleaned or replaced if necessary. Lubrication and maintenance intervals are given on the fan card supplied with the unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the TFV 600 suitable for dusty work?\u003c\/strong\u003e\u003cbr\u003eYes. The fan motor sits outside the main air flow, and TROTEC states that the fan can also be used in very dusty rooms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOriginal TROTEC equipment\u003c\/strong\u003e — supplied with full manufacturer documentation by BMB Rheinland, your authorised distribution partner.\u003c\/p\u003e\u003cp\u003ePlanning a project or a larger requirement? \u003ca href=\"\/pages\/contact\"\u003eRequest a quote\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/de.trotec.com\/fileadmin\/downloads\/Ventilation\/TFV600\/TRT-BA-TFV600-TC-001-DE.pdf\" target=\"_blank\"\u003e📄 Operating manual incl. EC declaration of conformity TROTEC TFV 600 (DE)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"TROTEC","offers":[{"title":"Default Title","offer_id":58787248996696,"sku":"1510002040","price":10055.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0962\/3932\/1432\/files\/Radialventilator-TFV-600-103981-1556806818.jpg?v=1791978875","url":"https:\/\/shop.bmbrheinlandgmbh.com\/products\/trotec-tfv-600-radial-fan","provider":"BMB Rheinland GmbH","version":"1.0","type":"link"}